Free Sensor Sample Order Now

Connector

Fujifilm Prescale® Film Placed Between a Connector Interface

Request a Free Sample

Fujifilm Prescale® is a thin flexible mylar film that reveals pressure distribution between and magnitude between any two contacting or mating surfaces. Fujifilm Prescale can reveal if pins on connector interface are seating properly between male/female interfaces and what exertion level is required to effect closure and full connection.

Upon the application of force the microcapsules rupture, producing an instantaneous and permanent color change. Like Litmus paper, the color intensity of Fujifilm Prescale is quantifiable; the color intensity reveals precisely what pressure level (PSI or kg/cm2) was applied at any discrete point on the surface of the film.

Have you ever needed to evaluate pressure or force between two touching or mating surfaces? Previously, your only alternatives were strain gauges and load cells, that are both time consuming and difficult to interface. Now with the advent of our disposable one-time use pressure film, Fujifilm Prescale®, evaluating surface contact pressure distribution and magnitude is accurate, quick and highly economical.

Pressure Film Type Code Alternative Code Pressure Range Order Now
Ultra Extreme Low 5LW UXL310 0.87 - 7.3 PSI (0.06 - 0.51 kg/cm2) Order Now
Extreme Low LLLLW / 4LW XL310 7.2 - 28 PSI (0.5 - 2 kg/cm2) Order Now
Ultra Low LLLW UL270 28 - 85 PSI (2 - 6 kg/cm2) Order Now
Super Low LLW SL270 70 - 350 PSI (5 - 25 kg/cm2) Order Now
Low LW L270 350 - 1,400 PSI (25 - 100 kg/cm2) Order Now
Medium MS M270 1,400 - 7,100 PSI (100 - 500 kg/cm2) Order Now
High HS H270 7,100 - 18,500 PSI (500 - 1,300 kg/cm2) Order Now
Super High HHS SH270 18,500 - 43,200 PSI (1,300 - 3,000 kg/cm2) Order Now
Physical Specifications
Operating Temperature 68°F - 95°F (20°C - 35°C) much higher for brief exposure
Humidity Range 20% to 90% RH
Gauge (Thickness) 4 - 20 mils
Spatial Resolution From 5 - 15 microns
Substrate Polyethylene Terephthalate (PET)
Accuracy ± 10% visual, ± 2%
Utilizing optional optical measurement systems
Shelf Life 1 Year